Is there cloging in the
refrigerant system ?
Correct refrigerant system
Is the supply voltage to the
outdoor unit control board
normal?
Check power voltage to control board
Is wiring connection from
control board to compressor
correct ?
Correct wiring connection
Is control board
working normal?
Check control board
Check compressor
Check code
Check code name
cause
Error 49
Compressor1 Inverter Driver Starting
Fail
There is a failure in the start command to operate
compressor 1.
Is there shortage or
high refrigerant in the
system ?
Correct refrigerant amount
Содержание CVIA-80-CPF3