Configuration for Utilizing Four (4) Sage Insertion
Mass Flow Meters for Large Round Pipes or Ducts Larger
than 36" to Minimize Effects of Varying Flow Profiles
(IT IS RECOMMENDED THAT FACTORY BE CONTACTED TO ASSIST WITH APPLICATIONS OF THIS NATURE)
The outputs of the four meters will be averaged
by customer’s PLC or other method to improve
overall accuracy in measuring the flow rate.
(For medium sized round pipes [18" to 36"],
two meters, on the opposite side of the same
diameter, may be sufficient [insert parallel to an
upstream 90 degree bend for optimal benefit.])
Note, in this configuration, each sensor needs
to be averaged.
Insert Probes 15% into
round pipe or duct