O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l
19
S A G E M E T E R I N G , I N C .
REV. 03-SIE/SRE
Junction Box Wiring Terminals for Remote Style Meters (Series SRG)
(THERE ARE NO ELECTRONICS INSIDE JUNCTION BOX)
CUSTOMER SIDE
1
(Wired at Installation Site)
FACTORY SIDE
(Wired at Factory)
Red
Red
White
White
Blue
Green
Red
Orange
Black
White
CAUTION: Strip wires 3/8" and
do not crimp insulation.
4.37
3/4” FNPT
Conduit Receptacle
Grounding Screw
GROUNDING SCREW NOT USED
(The shield [drain wire] is only connected
on the other end [the electronics end]).
Metal Conduit
is recommended
with appropriate
grounding to
minimize effects
from external
noise sources.
Interconnect Cable
2
To Terminal 1 to 6
SENSOR DRIVER BOARD NT STYLE (Remote Hookup)
(see pages 18 and 19)
SEE THE FOLLOWING PAGE FOR THE OTHER END OF THE REMOTE WIRING HOOKUP (the electronics side).
NOTE: The Sensor Junction Box
will have a serial number tag.
It is important to match this serial
number with the serial number of
the Remote electronics. Mixing
components from different meters
can result in significant errors.
a
CAUTION: Cable and cable glands are not for use in hazardous area
environments. Power, ground, outputs, shielded cable, seal fittings
and conduits are to be supplied by customer.
1
CSA standards require grounding this end as well. Refer to proper electrical code:
CEC Part 1
Appendix J18-100.
2
NOTE:
There are hidden jumpers (underneath the terminal strip) that short together the Blue
and Green wires, and also short together the Black and Orange wires. These extra wires are part of
the meter's Lead Length Compensation circuitry, allowing the user to change the length of the inter-
connect cable (from 0 to 1000 feet) without effecting the accuracy. 25 feet of cable are initially sup-
plied (for cabling longer than 1000 feet, contact Sage).
3
Sage supplies 25 feet of cable for the interconnect wires between the Junction Box and the Remote
Enclosures: Carroll (manufacturer), Part #C0783, 20 gauge, 6 conductor, foil shielded, grey PVC jacket.
Содержание SIE Series
Страница 2: ......
Страница 6: ......
Страница 7: ...Section GETTING STARTED A ...
Страница 8: ......
Страница 23: ...Section STYLES AND FEATURES B ...
Страница 24: ......
Страница 28: ......
Страница 29: ...Section DRAWINGS C ...
Страница 30: ......
Страница 39: ...Section USER INTERFACE D ...
Страница 40: ......
Страница 58: ......
Страница 59: ...Section DIAGNOSTICS E ...
Страница 60: ......
Страница 63: ...Section WARRANTIES AND SERVICE WORK F ...
Страница 64: ......
Страница 69: ...G Section APPENDIX G ...
Страница 70: ......