S A G E M E T E R I N G , I N C .
O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l
36
REV. 03-SIE/SRE
Optional Flanges
Flanges for 3
1
⁄
2
" pipe sizes and up,
have 8 bolt holes
Flanges for 3" pipe sizes and
smaller have 4 bolt holes
Flanged Ends (150#, 300#, or 600#) are optional on
In-Line Flow Meters. Otherwise, NPT Ends are sup-
plied. The Face-to-Face dimensions (“L”) of Flanged
Ends are identical to the lengths shown on the Table
on page 31. The table on page 31 applies either to
the standard NPT terminations or the Flanged Ends.
SIDE VIEW
BOLT PATTERN
Flanged mounting for Insertion Flow Meters is also
optional, although generally applied to very high
pressure or high temperature applications only.
Note, when specifying Flanged mounting for
Insertion Flow Meters, the Flange will be welded.
Therefore it is essential that a drawing is supplied
that clearly shows the height of the mating Flange
relative to the Pipe OD. The Pipe ID and Schedule
will also be required. Sage will fabricate Flanged
Insertion Meter so that the sensor lines up with the
center of the pipe when the Sage Flange is bolted
to the customer’s Flange.
Flanged Mounting for Insertion Meter
(OPTIONAL)
U
P
S
T
R
E
A
M
FLO
W
NOTE:
Flange bolt holes are lined
up with direction of flow
Содержание SIE Series
Страница 2: ......
Страница 6: ......
Страница 7: ...Section GETTING STARTED A ...
Страница 8: ......
Страница 23: ...Section STYLES AND FEATURES B ...
Страница 24: ......
Страница 28: ......
Страница 29: ...Section DRAWINGS C ...
Страница 30: ......
Страница 39: ...Section USER INTERFACE D ...
Страница 40: ......
Страница 58: ......
Страница 59: ...Section DIAGNOSTICS E ...
Страница 60: ......
Страница 63: ...Section WARRANTIES AND SERVICE WORK F ...
Страница 64: ......
Страница 69: ...G Section APPENDIX G ...
Страница 70: ......