© Sage Instruments 2000
9100-2930-02 01/31/00
5-32
Section V Option Menu Numbers
Option Menu #:
9
5-9 OPTION MENU #:9 WINK TIMING
OPTION MENU #:9, WINK TIMING is a standard feature
that enables timing of wink, pre-wink, and off-
hook supervision events. It is used with OPTION MENU #:2, SEND DIGIT SEQUENCES, OPTION
MENU #:4, DIGIT RECEIVER (Analog only), or OPTION MENU #:4, DIGIT Analyzer (PCM only).
To set wink timing:
1. Set up a digit sequence in OPTION MENU #:2, or set up the sequence to be received in OPTION
MENU #:4 and then outpulse the call.
3. Press the Option Menu function key.
4. Use the Up/Down Arrow keys to scroll through the option menus, OR select 9 using the
numeric keypad and then press the Option Menu function key. The display reads:
OPTION MENU #: 9 WINK TIMING
K1
K2
K3
K4
5. Press ENT or any soft key (K1-K4) to activate your selection. The display below shows a
sequence that was keyed-in under OPTION MENU #:2, SEND DIGIT SEQUENCES.
W 10 W 11 12 W H 250 msec GUARD
K1
K2
K3
K4
A flashing cursor appears over the last completed wink (
W
), off-hook (
H
), or failed event in the sequence.
If the sequence has not yet been outpulsed, all measurements will be zero.
There will be a measurement (
NNNN msec
) where
NNNN
is the length of time in milliseconds spent
waiting for the event (the guard time). The word
GUARD
is displayed to label the measurement. This is
the time from the previous event to the beginning of the wink. If the guard time exceeds 16 seconds,
the event “fails.” In such a case the
GUARD
display reads
>16000 msec
, and the wink or off-hook
measurement reads
FAILED
.
6. Use the Left/Right Arrow keys to move the cursor within the sequence to examine any
supervision event.
7. Use K4 to toggle between
GUARD
and
WINK
timing measurement (if the event is a Wink), or
GUARD
and
OFF HOOK
time measurement (if the event is an off-hook). The actual off-hook time
is not measured but merely a message that it exceeded the >2 sec threshold.
A wink fails if its duration is greater than
600 msecs
. An off-hook fails if its duration is less than
200
msecs
. You can also use Wink Timing to measure Delay Dial events as set up in OPTION MENU #:2
or OPTION MENU #:4. A Delay Dial event fails if the Guard period exceeds 16 seconds, or if the off-
hook period exceeds 16 seconds.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание 930i
Страница 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 19: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 43: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 203: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 235: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...