5-1
© Sage Instruments 2000
9100-2930-02 01/31/00
Sage Instruments 930i Communications Test Set
SECTION V
OPTION MENU NUMBERS
The following chart lists each Option Menu number with its description and the purchased option
necessary to receive that function if it is not a standard feature of the 930i.
Option
Menu #
Description
Purchased Option Required
1
MODIFY DIAL/RING
STANDARD (analog only)
2
SEND DIGIT SEQUENCES
STANDARD (analog only)
3
REMOTE CONTROL
STANDARD
4
DIGIT ANALYZER
STANDARD (analog only)
4
CALL ANALYZER
STANDARD (PCM only)
5
RING LOAD
PURCHASED OPTION 930i-13 Ring Generator
6
DC VOLT/AMP METER
STANDARD (analog only)
7
SUPERVISION THRESHOLDS
STANDARD (analog only)
9
WINK TIMING
STANDARD (analog only)
10
FREQUENCY SWEEP
STANDARD
11
IMPULSE NOISE & HITS
PURCHASED OPTION 930i-100, Data Test Package
12
WINK MARGINING
STANDARD (analog only)
13
PHASE/AMPLITUDE JITTER
PURCHASED OPTION 930i-100, Data Test Package
14
SET TIME AND DATE
STANDARD
15
BEEP ON ERR?
STANDARD
16
DIGIT RECEIVER TIMEOUT
STANDARD (analog only)
17
ENVELOPE DELAY DISTORTION
PURCHASED OPTION 930i-100, Data Test Package
18
P/AR RATIO
PURCHASED OPTION 930i-100, Data Test Package
19
4-TONE INTERMODULATION
PURCHASED OPTION 930i-100, Data Test Package
20
30 BIT DISPLAY
STANDARD
21
TOGGLE ABCD BITS
STANDARD
22
ABSOLUTE DELAY
PURCHASED OPTION 930i-21, Absolute Delay
24
POST TPT DELAY
PURCHASED OPTION 930i-12 ROTL Responder, 105E
25
FAR END RESPONDER
PURCHASED OPTION 930i-12 ROTL Responder, 105E
26
ROTL/RESPONDER
PURCHASED OPTION 930i-12 ROTL Responder, 105E
27
ROTL/INTERROGATOR
PURCHASED OPTION 930i-12 ROTL Responder, 105E
29
CALL 102 LINE
STANDARD
30
ADJUST TLP
STANDARD (analog only)
31
SEND HOOK FLASH
STANDARD (analog only)
32
DIAL-UP TESTLINE
STANDARD
33
DIAL-UP SWEEP
STANDARD
34
SELECT REPORTS
STANDARD
35
DUAL TONE SENDER
STANDARD
37
LINE STATUS
STANDARD (analog only)
39
REMOTE AUDIO
PURCHASED OPTION 930i-47 REMOTE AUDIO
40
SEND PCM ALARMS
STANDARD
41
READ E-1 VOLTAGE
STANDARD
43
E-1 ERROR COUNTERS
STANDARD
44
E-1 ERROR HISTORY
STANDARD
45
E-1 ERROR INJECT
STANDARD
46
E-1 BIT ERROR RATE
STANDARD
55
FRACTIONAL E-1 BERT
PURCHASED OPTION 930i-51, Fractional E-1 BERT
56
64-KBIT E-1 BERT
PURCHASED OPTION 930i-23, Extended Bit Error Rate
59
ECHO CANCELLER DISABLE
STANDARD
O
ption Menu
Numbers
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание 930i
Страница 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 19: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 43: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 203: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 235: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...