5-109
© Sage Instruments 2000
9100-2930-02 01/31/00
Sage Instruments 930i Communications Test Set
2. Press K3 under
SET ERR
once and you will see a display similar to:
0 BIT ERRS PCM1 INJ-ERR EXIT
K1
K2
K3
K4
3. Press K3 under
INJ-ERR
to inject an error.
4. Press K4 to exit this display.
5-55.2.2 Testing True-Noncontiguous Channels
To continue testing true-noncontiguous channels:
1. Press K4 under
MENU
. The display reads:
SELECT: SYN-STAT ERR-STAT INJ-ERR EXIT
K1
K2
K3
K4
2. Press K1 under
SYN-STAT
to view the synchronization status, OR press K2 under
ERR-STAT
to view the error results.
If you selected
SYN-STAT
, the display reads:
SYNC: 123456789 0123456789 0123456789 0
K1
K2
K3
K4
The display shows the synchronization status for up to 30 channels on the E1 under test. A 0 indicates
that the indicated channel is synchronized, while a 1 indicates that the channel is not synchronized. A
- indicated that the channel is not enabled.
If you selected
ERR-STAT,
the display reads:
ERRS: 123456789 0123456789 0123456789 0
K1
K2
K3
K4
The display shows the error status for up to 30 channels on the E1 under test. A 0 indicates the absence
of an error or errors on the indicated channel, while a 1 indicates the presence of an error. A - indicated
that the channel is not enabled.
Option Menu #:
55
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание 930i
Страница 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 19: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 43: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 203: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 235: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...