© 2004 SAGE INSTRUMENTS
9100-0925-01 V1.2
42
S
ETUP
s [circuit ID, 'User ID', 'work order']
Use the setup command to setup information that gets passed to the responder as part of
the test.
The
circuit ID
is the phone number of the 925VST performing the test. This is required for
tests that have call-back enabled. The
User ID
is a 20-character alphanumeric field that can
contain any user identification information desired. The contents of this field must be in
single quotes. The
work order
is a 20-character alphanumeric field that can contain any
information desired. The contents of this field must be enclosed in single quotes.
An acknowledgment of the command and the parameters is sent:
Setup: CID:Circuit Id, UID:User Id, W/O:Work Order
E
XIT
x
This exit command exits out of the remote control interface and restores the inactivity
timeout timer to normal operation. Note that there are two exit commands; the other is
listed below.
P
RINT
p
The print command prints the results of the last test.
E
XIT
e
This exit command causes a continuous test to complete. Note that there are two exit
commands; the other is listed above.
Using the 925VST as a Telephone
When the 925VST is connected to a working phone line, you can use it as a telephone
handset. A telephone speaker and microphone are located on the back of the 925VST. The
speaker volume is automatically adjusted to a level suitable for use as an earphone.
NOTE: When the 925VST is connected to a working phone line, it can receive telephone
calls even when it is turned off.
To use the 925VST as a telephone:
1. Use the supplied cord to connect the 925VST to an operating phone line.
2. Press the TALK key, and listen for a dial tone.
The display shows the last number dialed. The 925VST goes off hook, and the
alpha-numeric keypad functions just like a telephone keypad. At any time, press
the TALK key again to disable the telephone function.