![background image](http://html1.mh-extra.com/html/sage/925vst/925vst_user-manual_3446367033.webp)
© 2004 SAGE INSTRUMENTS
9100-0925-01 V1.2
33
100:SMOS.01 1
¾
1:<SMOS Director>
P
2:DVM P
3:Call Progress
P
Work Order #
Result Types
100:SMOS.01 2
½
1:Test Info
2:Print Results
Work Order #
Result Type
Print Test
Results
View SMOS Results
1:<Near>
2:Far
SMOS Director N 1
¾
MOS:
4.57
P
Noise:
18 dBrnC P
-FS:
0 ms F
4. Use the keypad to select the test result type that you want to view.
For each test, you can view detailed results specialized for that test (e.g., SMOS
Director), or you can view results for DVM (digit volt meter), call progress, test
info. Use the
S
and
T
keys to scroll through the list of available test result types.
For information on specific test result types, see the following section,
In steps 3 and 4, you can use the CLR key to delete the currently viewed work order result
file. The last entry in the list is used to print or export all captured results for a selected test
using an RS-232 connection.
Test Result Types
Test Result Types
Test Result Types
Test Result Types
Each test has a detailed results specialized for that particular test. The following section
describes the options and display screens that are available once you have selected a test in
step 4 above.
SMOS D
IRECTOR
Once you select the SMOS Director test results, you
can view near end and far end test results.
•
Near results are results of measurements made at
the customer site.
•
Far results are results of measurements made at
the central office.
The results for SMOS Director are shown over three screens. While viewing a screen, you
can use the F1 (near) and F2 (far) keys to toggle between near and far results for the same
screen. If templates are enabled (see Template on
page 15), a P or F will show in the last column and
indicate pass or fail respectively.
•
MOS: Mean Opinion Score — Voice clarity
merit score [1.00 to 5.00]
•
Noise: Comfort Noise