75
Unless stated otherwise, all dimensions are given in mm.
MANTO®
6 Infills (typical solutions)
This section shows different ways to construct infills.
For information on infills up to 60 mm, see below.
For information on infills up to 80 mm, see page 76.
For information on infills up to 150 mm, see page 76.
For information on infills up to 300 mm, see page 77.
The following illustration and table show information needed to select the proper infill.
Top view
a)
1/2
1/2
1/2
1/2
Area of influence (IW)
Panel
Panel
a) Infill
Max. area of influence (IW) for infill with a single tie (see solutions 6.1, 6.2, and 6.3)
Panel height
Pressure profile
Max. EB
Connectors per panel*
DW 15
DW 20
2.70 m
Hydrostatic
1.30 m
1.50 m
2
Constant
1.20 m
1.40 m
2
3.30 m
Hydrostatic
1.05 m
1.50 m
2
Constant
1.00 m
1.20 m
2
Constant pressure for DW 15 = 60.00 kN/m
2
, for DW 20 = 80.00 kN/m
2
.
* Additional connectors might be required due to timber and joint capacity.
6.1 Infills up to 60 mm wide
max.: 60
See table for max. EB
MANTO Tie Nut
(code:464600)
Tie Rod DW 15
Adjustable Aligning Clamp
(code:467898)
or PLATINUM 100 Universal Connector
(code:606209)
Always centre the tie on the infill.
The tie washer must overlap the panels by at least 35 mm.
Содержание Huennebeck MANTO G3
Страница 1: ...MANTO Large frame panel formwork User guide...
Страница 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Страница 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...
Страница 219: ...219 Unless stated otherwise all dimensions are given in mm MANTO...