203
Unless stated otherwise, all dimensions are given in mm.
MANTO®
Step 4
Once the formwork is at the point of use, use suitable ties to anchor the alignment
struts firmly to the ground.
Suitable anchors
to the ground.
Step 5
If required, attach further MANTO panels, anchor to the ground (A) and connect to the
first panels with Aligning Panel Clamps (B).
Step 6
Connect the proper platform, in this case the MANTO Pouring Platform, with the inte-
grated railing to the formwork (C).
B
A
C
MANTO Pouring Plat-
form (code:547165)
End guardrails not
shown for clarity.