150
Column formwork
Unless stated otherwise, all dimensions are given in mm.
The MANTO Column Angle Walers must be fastened through the tie hole with a Col-
umn Waler Bolt and a Waler Wedge on each of the four panels. This determines the
position and quantity of the walers.
Column Waler Bolt
(code:569189)
Tie hole
MANTO Column
Angle Waler
(code:540005)
Locking pin
Column Waler
Wedge
(code:540049)
Column Waler Wedge
(code:540049)
Column
Waler Bolt
(code:569189)
After assembling the panels, the MANTO Column Angle Walers must be mounted. The
spacing of the MANTO Column Angle Walers should be adjusted to the desired column
dimension by using the captive safety pin.
Finally, by installing the tie (2no. MANTO Tie Nuts and 1no. Tie Rod DW 15, 500 mm) the
column formwork is closed and ready to use.
Locking pin
MANTO Column Angle
Waler (code:540005)
MANTO Tie Nut
(code:464600)
Tie Rod 500
mm
(code:102527)
MANTO Column Angle
Waler
(code:540005)