215
Unless stated otherwise, all dimensions are given in mm.
MANTO®
Step 2
Place additional Uni mesh panels (up to 50 panels, depending on the size) in the Uni
Mesh Panel Rack.
Do not stack more than 2no. Uni Mesh Panel Racks on top of one another.
Always use a 4-strand chain sling to transport by crane!
20.4.4 PROTECTO mesh panels
PROTECTO mesh panels should be stored in the PROTECTO Mesh Panel Rack. The
PROTECTO mesh panels have to be secured with the insertion tube to prevent them
from slipping during transport. The PROTECTO Mesh Panel Rack cannot be moved with
the Euro Trolley.
The PROTECTO mesh panels must be place on top of one another without any gaps
and flush to one another. Otherwise the PROTECTO mesh panels cannot be secured
with the insertion tube. Transport is permitted only with the insertion tube in place.
The following quantities of PROTECTO mesh panels can be stored and transported in
the PROTECTO Mesh Panel Rack:
PROTECTO Mesh Panel 263:
49 pcs.
PROTECTO Mesh Panel 240:
54 pcs.
PROTECTO Mesh Panel 180:
60 pcs.
PROTECTO Mesh Panel 130:
60 pcs.
Step 1
Remove the insertion tube (
A
) from the PROTECTO Mesh Panel Rack.
A
Содержание Huennebeck MANTO G3
Страница 1: ...MANTO Large frame panel formwork User guide...
Страница 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Страница 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...
Страница 219: ...219 Unless stated otherwise all dimensions are given in mm MANTO...