135
Unless stated otherwise, all dimensions are given in mm.
MANTO®
11.4 T-wall connection
When pouring concrete against an existing wall, it is advisable to use the MANTO Cor-
ner Adjustment 5. This allows standard equipment to be used and the regular materials
to be used for tying.
WARNING
Warning!
1. The existing wall must be capable of withstanding the additional load and, if
required, it has to be braced adequately.
2. The formwork may have to be secured to prevent movement, e.g. by anchoring it to
an existing structure.
NOTE
MANTO G3 M panels can seesaw!
Because the panels are tied in the middle, an asymmetric load can cause the panels to
seesaw.
Use only MANTO G3 M panels ≤ 1.20 m for wall connections. Use MANTO G3 panels or
MANTO G3 M panels 240 as an alternative for wall connections.
Pouring direction
G3 M
G3 M
NOTE
1. The existing wall must be capable of withstanding the additional load and, if
required, it has to be braced adequately.
2. The formwork may have to be secured to prevent movement, e.g. by anchoring it to
an existing structure.