109
Unless stated otherwise, all dimensions are given in mm.
MANTO®
Pin clip
Tie nut
advancing side
Tie rod
With pin clip inserted
Without pin clip inserted
Depending on this, the following wall thicknesses can be preset without measuring:
PLATINUM 100 Tie
Nut Advancing Side
Adjusting positions PLATINUM 100 tie rod/wall thickness [mm]
1
2
3
4
5
6
7
Without pin clip
150
175
200
225
250
275
300
With pin clip
275
300
325
350
375
400
425 (a)
(a) Only possible with the G1 clip.
Step 1
To set the desired wall thickness, position the adjusting washer in the appropriate
adjusting groove.
1
Adjusting washer
Selected adjusting groove
Step 2
Screw the adjusting washer on the tie into the adjusting washer to secure the pre-
selected position.
2
Adjusting washer