180
Shaft formwork
Unless stated otherwise, all dimensions are given in mm.
Step 2
Turn the adjustment screw, until the holes in the hexagon nut point to the top of the
MANTO Shaft Corner.
Step 3
Pull out the spring pin (
1
) from the lower MANTO Shaft Corner. The uppermost MANTO
Shaft Corner remains in the original position.
1
Step 4
Screw the upper Counter Nut (
2
) downward until it reaches the lower Counter Nut (
3
).
Insert the spring cotter pin (
1
) in the hole directly above the upper Counter Nut.
1
2
3