138
Stopends
Unless stated otherwise, all dimensions are given in mm.
The following table shows the quantity of Outer Corner Clamps needed at the stopends
and the connectors needed in the section 1, which is subjected to a higher tensile load.
Stopend
MANTO panel
(Height)
Wall thickness ≤ 300 mm
Stopend
Area 1 < 500 mm
No. of Outer Corner
Clamps
No. of Aligning Panel
Clamps
2.70 m
4
2
3.30 m
5
2
2.70 m / 1.20 m
4/2
2/1
3.30 m / 1.20 m
5/2
2/2
2.70 m / 2.70 m
4/4
3/2
2.70 m / 3.30 m
4/4
3/2
3.30 m / 3.30 m
5/4
3/2
Area 1
Regular area
Connector,
e.g. MANTO Aligning Panel Clamp
(code:448000)
Stopend
≤ 300
All information shown above is valid for concrete of normal consistency with an
assumed coefficient of friction of μ = 0.20 between the concrete and formwork. Liquid
concrete and concrete with low consistency must be checked separately.