LIFT MODEL VISION AS 300 Rev001
10-9
By
pressing
the
rise/descent push-button
the elevator does not
move
The phases have been inverted
Invert the phase by operating
on the plug fitted on the electric
panel
Total current failure
Check and be sure that the
control electric panel is live
Some limit switches have tripped
Inspect
the
following
limit
switches:
a) rise limit switch
b) descent limit switch
c) door closing control limit
switch
d) vertical element presence
controlling limit switch
During the rise/descent
you
can
hear
hum
emitted by the electric
motors
Humidity in the safety system electro-magnet
Operate
repeatedly
the
rise/descent
lever.
If
the
problem persists replace the
electro-magnet.
When the push-button
during the descent is no
longer
pressed
the
elevator does not stop
immediately and instead
the
emergency
brake
gets activated)
The electro-magnetic brake of the electric
motor is worn or it has lost power
Call immediately the closer
assistance point in your area or
the manufacturer
During
the
rise
the
machine does not stop,
but instead, by pressing
the
descent
lever
descends
The limit switch which controls the vertical
element presence has been
activated. Set the limit switch
appropriately
Table 10 : Inconveniences to the electric installation
ATTENTION:
All intervention on the electric installation must be carried out by
qualified personnel only obeying the safety rules over the electric
installations, in order to avoid accidents and injuries to the
operators!
Содержание VISION AS 300
Страница 2: ......
Страница 4: ......
Страница 43: ...LIFT MODEL VISION AS 300 Rev001 7 4 Fig 7 1 Dimension...
Страница 68: ...LIFT MODEL VISION AS 300 Rev001 12 1 12 WIRING DIAGRAMS Fig 12 1 Wiring diagram Power supply...
Страница 69: ...LIFT MODEL VISION AS 300 Rev001 12 1 Fig 12 2 Wiring diagram Motor power supply...
Страница 70: ...LIFT MODEL VISION AS 300 Rev001 12 2 Fig 12 3 Wiring diagram Emergency circuit...
Страница 71: ...LIFT MODEL VISION AS 300 Rev001 12 3 Fig 12 4 Wiring diagram Auxiliary...
Страница 72: ...LIFT MODEL VISION AS 300 Rev001 12 4 Fig 12 5 4 Wiring diagram Auxiliary PLC logo expans...
Страница 73: ...LIFT MODEL VISION AS 300 Rev001 12 5 Fig 12 6 Auxiliary circuit...
Страница 74: ...LIFT MODEL VISION AS 300 Rev001 12 6 Fig 12 7 Wiring diagram Connectors C1 C2 C3...
Страница 75: ...LIFT MODEL VISION AS 300 Rev001 12 7 Fig 12 8 Wiring diagram Terminal box electric panel...
Страница 76: ...LIFT MODEL VISION AS 300 Rev001 12 8 Fig 12 9 Wiring diagram Cable call floor...
Страница 77: ...LIFT MODEL VISION AS 300 Rev001 12 9 Fig 12 10 Wiring diagram Floors call connection...
Страница 78: ...LIFT MODEL VISION AS 300 Rev001 12 10 Fig 12 11 Wiring diagram Box floor call connection...
Страница 79: ...LIFT MODEL VISION AS 300 Rev001 12 11 Fig 12 12 Wiring diagram Box Fencing connection...
Страница 80: ...LIFT MODEL VISION AS 300 Rev001 12 12 Fig 12 13 Wiring diagram Cable fancing call...
Страница 81: ...LIFT MODEL VISION AS 300 Rev001 12 13 Fig 12 14 Main electrical box components...
Страница 82: ...LIFT MODEL VISION AS 300 Rev001 12 14 Fig 12 15 Material list 1...
Страница 83: ...LIFT MODEL VISION AS 300 Rev001 12 15 Fig 12 16 Material list 2...