172
Commissioning maintenance-free batteries (MF)
The steps described below must be strictly observed in order to guarantee the long lifespan of the battery.
Work steps:
Pull the shut-off plug of the battery from the acid pack and remove the aluminium foil used to seal the battery (once the alumini-
um foil has been removed, the battery must be fi lled immediately!)
Insert the acid pack into the fi ller opening of the battery and allow the acid to run into the battery (keep the acid pack in this posi-
tion for at least 20 minutes).
Remove the acid pack from the battery and allow the battery to degas for another 20 minutes.
insert in the fi ller
openings
immediately
container with
electrolyte
container with
electrolyte
air bub-
bles
ELECTRICAL SYSTEM