Hardware Installation and Reference Guide
Overview
Slot for functional module
Multiple as required (at most four NMX modules and four SIC modules can be
configured)
Slot for power module
2 (at most two modules can be configured)
External dimension (W x H
x D)
440 mm x 161.4 mm x 412 mm (excluding the hangers on both sides)
Input voltage
AC100–240V 50–60Hz
Total power consumption
< 150 W
Operating temperature
0 to 40°C
Storage temperature
-40 to 70°C
Operating humidity
20–90%RH (non-condensing)
Slot Numbering
The slots of NMX moudle are numbered as below:
On the front panel, the slot for control board is numbered 0, and the rest numbered 1 to 4 from left to right and from
bottom to up, as shown in the following figure.
The slots of SIC moudle are numbered as below:
The slots of SIC moudle are located on the control module. On the front panel, the slots are numbered 5 to 8 from left to
right and from bottom to up, as shown in the following figure.
Supported Modules List
The following tables shows the modules supported on the RSR30-44:
Slot Number
Line Card Supported
Remarks