36
Deploying the Access Point
Step 2: Complete the Power Connections
Figure 20.
Strip the AC cable and the three conductors
5.
Insert the stripped part of the conductors into the appropriate terminals on the
connector housing. The conductors are color-coded and must be connected to the
appropriate terminals (see
Figure 21
and
Table 7
).
Figure 21.
Pinout connections
NOTE:
The color coding of wire conductors varies by region. Before completing this step,
check your local wiring standards for guidance.
6.
Using a small screwdriver, tighten the small screws around the connector housing to
fix the connector pins into the terminals.
7.
Mate the cable gland with the connector housing, and then tighten.
Table 7.
AC cable connector pins
Terminal #
Color
(Ground)
Green (US), Green/Yellow (EU)
1 (Neutral)
White or Gray (US), Blue (EU)
2 (Line)
Black (US), Brown (EU)
3 (Not Used)
4-5mm (max)
7/32 inches (max)
Содержание ZoneFlex 7762