Configuring the Access Point
Configuring for Standalone Operation or for Management by FlexMaster
5.
Insert the stripped part of the conductors into the appropriate terminals on the
connector housing. The conductors are color-coded and must be connected to the
appropriate terminals (see
Figure 13
and
Table 4
).
Figure 13.
Pinout connections
NOTE:
The color coding of wire conductors varies by region. Before completing this step,
check your local wiring standards for guidance.
6.
Using a small screwdriver, tighten the small screws around the connector housing to
fix the connector pins into the terminals.
7.
Mate the cable gland with the connector housing, and then tighten.
Figure 14.
AC connector assembly
Table 4.
AC cable connector pins
Terminal #
Color
(Ground)
Green (US), Green/Yellow (EU)
1 (Neutral)
White or Gray (US), Blue (EU)
2 (Line)
Black (US), Brown (EU)
3 (Not Used)