![Ruckus Wireless ICX 7150-24 Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/ruckus-wireless/icx-7150-24/icx-7150-24_hardware-installation-manual_1498875100.webp)
TABLE 26 Temperature thresholds (continued)
Model
Low limit temperature
High limit temperature
Critical (shutdown) temperature
PoE PSU: 49°C (120°F)
PoE PSU: 57°C (135°F)
ICX 7150-48PF
85°C (185°F)
PoE PSU: 34°C (93°F)
95°C (203°F)
PoE PSU: 41°C (106°F)
105°C (221°F)
ICX 7150-48ZP
85°C (185°F)
PoE PSU: 34°C (93°F)
95°C (203°F)
PoE PSU: 41°C (106°F)
105°C (221°F)
To display the temperature of a device, enter the
show chassis
command at any level of the CLI. The
show chassis
command displays the
current temperature, the power supply status, and temperature threshold levels. The displayed temperature reflects the temperature of the
board inside the device.
device# show chassis
The stack unit 1 chassis info:
Power supply 1 (AC - PoE) present, status ok
Model Number: YM-1921AB06R
Serial Number: SA000V171708000081
Firmware Ver: P2H802A00
Power supply 1 Fan Air Flow Direction: Front to Back
Power supply 2 (AC - PoE) present, status ok
Model Number: YM-1921AB06R
Serial Number: SA000V171708000083
Firmware Ver: P2H802A00
Power supply 2 Fan Air Flow Direction: Front to Back
Fan 1 ok, speed (manual): 1<->[[2]]
Fan 2 ok, speed (manual): 1<->[[2]]
Fan controlled temperature:
Rule 1/2 (MGMT THERMAL PLANE): 60.7 deg-C
Rule 2/2 (PoE THERMAL PLANE): 10.0 deg-C
Fan speed switching temperature thresholds:
Rule 1/2 (MGMT THERMAL PLANE):
Speed 1: NM<----->95 deg-C
Speed 2: 85<----->105 deg-C (shutdown)
Rule 2/2 (PoE THERMAL PLANE):
Speed 1: NM<----->41 deg-C
Speed 2: 34<----->105 deg-C (shutdown)
Fan 1 Air Flow Direction: Front to Back
Fan 2 Air Flow Direction: Front to Back
Slot 1 Current Temperature: 61.7 deg-C (Sensor 1), 54.4 deg-C (Sensor 2), 10.0 deg-C (Sensor 3)
Slot 2 Current Temperature: NA
Warning level.......: 102.0 deg-C
Shutdown level......: 105.0 deg-C
Boot Prom MAC : 609c.9fe2.154c
Management MAC: 609c.9fe2.08d6
Monitoring the Device
Monitoring power and cooling
Ruckus ICX 7150 Switch Hardware Installation Guide
100
Part Number: 53-1004928-05
Содержание ICX 7150-24
Страница 6: ...Ruckus ICX 7150 Switch Hardware Installation Guide 6 Part Number 53 1004928 05 ...
Страница 10: ...Ruckus ICX 7150 Switch Hardware Installation Guide 10 Part Number 53 1004928 05 ...
Страница 82: ...Ruckus ICX 7150 Switch Hardware Installation Guide 82 Part Number 53 1004928 05 ...
Страница 90: ...Ruckus ICX 7150 Switch Hardware Installation Guide 90 Part Number 53 1004928 05 ...
Страница 114: ...Ruckus ICX 7150 Switch Hardware Installation Guide 114 Part Number 53 1004928 05 ...
Страница 123: ... 2018 ARRIS Enterprises LLC All rights reserved 350 West Java Dr Sunnyvale CA 94089 USA www ruckuswireless com ...