Reference Manual
00809-0100-4024, Rev BA
September 2005
Rosemount 5600 Series
2-2
INTRODUCTION
This section describes the mechanical installation. Start by reading the
General Installation Requirements for your antenna. This includes Nozzle and
Free Space Requirements. The last part of this section includes mounting
instructions for all antenna types, including special requirements for still
pipe/bridle installations and applications.
Tools
The following set of tools are needed for installation of a 5600 Series Radar
Level Transmitter:
•
Screw driver.
•
Adjustable wrench.
•
Allen key.
•
Circlip plier (snap ring plier).
•
Hook spanner (comes delivered with the transmitter).
GENERAL
INSTALLATION
REQUIREMENTS
Position the transmitter in a way that allows the microwaves to propagate
without disturbance from the tank wall. In order to achieve optimum
performance you should consider the following recommendations:
•
Try to avoid obstacles in the radar beam.
•
Mount the transmitter away from pipe inlets which cause turbulent
conditions.
•
Choose as large antenna as possible to ensure maximum antenna
gain.
•
For best measurement performance it is recommended that the
antenna tip ends outside the nozzle, see Figure 2-2.
Customer Supplied
Flanges
The simple design of cone and rod antennas tank connection allows the use
of customer supplied flanges. If a hole is drilled in a standard blind flange the
pressure performance may be reduced. In such a case the flange should be
marked with new rating for Maximum Allowed Working Pressure (MAWP).
Failure to follow safe installation and servicing guidelines could result in death or
serious injury:
Make sure only qualified personnel perform these procedures.
Use the equipment only as specified in this manual. Failure to do so may impair the
protection provided by the equipment.
Do not perform any service other than those contained in this manual unless you are
qualified.
The quartz seal is not suitable for use in environments where there is a risk for variations or
other mechanical impacts.
For quartz seal, mechanical shocks may permanently damage the seal. A damaged tank
seal must be replaced. Replacement must be done when the tank is unpressurized.
The customer must always make sure that exposed material of antenna and tank seal is
compatible with the tank content, e.g. the quartz seal is not suitable for use with
Hydrofluoric acid (HF).
A damaged quartz tank seal will typically cause one or many disturbance echoes which will
be seen in a tank spectrum plot during gauge configuration.
Содержание 5600 Series
Страница 2: ......
Страница 4: ......
Страница 18: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 1 10 ...
Страница 64: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 2 46 ...
Страница 80: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 3 16 ...
Страница 99: ...Reference Manual 00809 0100 4024 Rev BA September 2005 4 19 Rosemount 5600 Series ...
Страница 100: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 4 20 ...
Страница 130: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 6 20 F OUNDATION Fieldbus ...
Страница 144: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 7 14 2210 Display Unit ...
Страница 174: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series A 20 ...
Страница 185: ...Reference Manual 00809 0100 4024 Rev BA September 2005 B 11 Rosemount 5600 Series 5600APPROVAL03 EPS ...
Страница 186: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series B 12 5600APPROVAL04 EPS ...
Страница 196: ...Reference Manual 00809 0100 4025 Rev BA April 2002 Rosemount 5600 Series C 8 F OUNDATION Fieldbus ...
Страница 204: ...Reference Manual 00809 0100 4025 Rev BA September 2005 Rosemount 5600 Series E 4 F OUNDATION Fieldbus ...
Страница 208: ...Reference Manual 00809 0100 4024 Rev BA March 2004 Rosemount 5600 Series Index 4 ...
Страница 209: ......