Rose Point Radar Installation Guide
12
Interconnecting cable (Open scanner)
1.
Be sure that the power is off. Connect the cable to the plug labeled “SCANNER” on the control
box. Be sure to secure the rubber boot around the cable connector rim.
2.
Use a socket wrench to remove the back cover of scanner unit.
3.
Remove the two bolts securing the transceiver.
4.
Remove the connectors to the motor (X1: RB716A, J5:RB717A/718A) and to the heading switch
(X2: RB716A, J3: RB717A/718A). Pull out the transceiver.
5.
Remove the four bolts securing the fixing plate at the cable entrance.
6.
Remove the metal fixing plate, rubber seal and washer that secure the cable. Pass the cable
through as shown in the diagram below; replace the above items and tighten the bolts.
7.
Return the transceiver to its original position and secure it with the bolts you removed.
8.
Connect the 7-pin connector to X11 (RB716A)/J2 (RB717A/718A) and the 9-pin connector to X12
(RB716A)/J1 (RB717A/718A) of the printed circuit board and connect the two connectors that
you removed in Step 4.
9.
Reattach the scanner cover. Take care not to pinch the cable when reattaching the cover.
Содержание MDS-51
Страница 13: ...Rose Point Radar Installation Guide 10 Attaching the Cover Radome scanner ...
Страница 14: ...Rose Point Radar Installation Guide 11 Attaching the interconnecting cable Radome Scanner ...
Страница 16: ...Rose Point Radar Installation Guide 13 Attaching the interconnecting cable Open Array Scanner ...
Страница 26: ...Rose Point Radar Installation Guide 23 Specifications Radar Sensor Unit Power Interface ...
Страница 27: ...Rose Point Radar Installation Guide 24 Drawings Interconnection Diagram ...
Страница 28: ...Rose Point Radar Installation Guide 25 RB715A Scanner Unit ...
Страница 29: ...Rose Point Radar Installation Guide 26 RB716A Scanner Unit ...
Страница 30: ...Rose Point Radar Installation Guide 27 RB717A 718A Scanner Unit ...
Страница 31: ...Rose Point Radar Installation Guide 28 MDS 5 MDS 6 Control Box ...