Rose Point Radar Installation Guide
9
Connecting the Scanner to the Control Box
Lay cables firmly in place by following the instructions below:
Notes:
1.
Do not bind the cable for the radar collectively with cables of other equipment (especially the
power supply cable).
2.
Leave clearance near the inlet of the display so you can remove the control box easily. This
facilitates installation and maintenance of the control box.
3.
Because the cable has a connector on both sides, if it is necessary to pass cable through a narrow
path, use vinyl tape to affix the scanner-side connector to the cable before passing the cable
through the path.
4.
Lay cable along the ship’s hull or wall surface and attach it in place at intervals of about 40 cm.
Interconnecting Cable (Radome scanner)
1.
Be sure that the power is off. Connect the cable to the plug labeled “SCANNER” on the control
box. Be sure to secure the rubber boot around the cable connector rim.
2.
Remove the upper part of the radome from the scanner unit. Lift it vertically to avoid bumping it
against the antenna. (There are four screws to remove first.)
3.
Remove the tape securing the antenna.
4.
Remove the shield cover located on the backside. (There are four screws to remove first.)
5.
Remove the cable clamping plate and rubber ring, pass the cable through the opening, replace
the rubber ring, and clamp the cable to the scanner unit with screws on the fixing plate. Attach
the 7-pin connector to X11 and 9-pin connector to X12 of the printed circuit board.
6.
Replace the aluminum cover. Lay the cable shield into the channel machined into the aluminum
housing. Be careful that the cable will not get caught up between the main unit and the cover.
7.
Replace the upper part of the radome being careful not to bump it against the antenna. Make
sure that the cover is positioned in the correct direction. The upper and lower parts of the
radome each have four alignment markings indicating screw positions.
Содержание MDS-51
Страница 13: ...Rose Point Radar Installation Guide 10 Attaching the Cover Radome scanner ...
Страница 14: ...Rose Point Radar Installation Guide 11 Attaching the interconnecting cable Radome Scanner ...
Страница 16: ...Rose Point Radar Installation Guide 13 Attaching the interconnecting cable Open Array Scanner ...
Страница 26: ...Rose Point Radar Installation Guide 23 Specifications Radar Sensor Unit Power Interface ...
Страница 27: ...Rose Point Radar Installation Guide 24 Drawings Interconnection Diagram ...
Страница 28: ...Rose Point Radar Installation Guide 25 RB715A Scanner Unit ...
Страница 29: ...Rose Point Radar Installation Guide 26 RB716A Scanner Unit ...
Страница 30: ...Rose Point Radar Installation Guide 27 RB717A 718A Scanner Unit ...
Страница 31: ...Rose Point Radar Installation Guide 28 MDS 5 MDS 6 Control Box ...