Controller functions
Version 1
RES-409
Page 47
The "OUTPUT" LED blinks repeatedly while the "AUTOCOMP" function is running and the actual value output
(terminals 17+18) is set to 0…3°C (corresponds to approx. 0VDC).
The "AUTOCOMP" function must be activated either in the ROPEX visualization software
(
section 10.12 "Diagnostic interface / visualization software (as of February 2007)" on page 50) or
via the CAN interface (CAN message address 13) (default setting: AUTOCOMP off).
10.9
Temperature monitoring / "temperature OK" bit (as of February 2007)
In control mode (START is active), the RES-409 checks whether the ACTUAL temperature is within a settable
tolerance band ("OK" window) either side of the SET temperature.
The "Temperature OK" function is specified in CAN message address 9. The lower and upper tolerance band
limits (
) can be varied between 3 and 99°C (up to January 2007: 3…20°C) with CAN message address 7. The
upper and lower tolerance band limits can also be set independently of one another on controllers manufactured
as of February 2007 (CAN message addresses D and E).
The following settings are possible:
1.
"Off"
"Temperature OK" bit has no function.
2.
"Active if Tact = Tset" (factory setting)
The "Temperature OK" bit (bit 3) in the controller status (
section 10.4.1 "Controller status" on page 39) has
the value "1" if the actual value is inside the specified temperature tolerance band (CAN message address 7
or addresses D and E). If the actual temperature is outside the tolerance band, the "Temperature OK" bit has
the value "0" (see graph below).