Controller functions
Page 50
RES-409
Version 1
The heatup timeout cannot be started with the 24VDC START 1 signal. This signal has no function
here.
The heatup timeout must be activated either in the ROPEX visualization software (
"Diagnostic interface / visualization software (as of February 2007)" on page 50) or via the CAN
interface (CAN message address 11) (default setting: heatup timeout off).
10.12 Diagnostic interface / visualization software (as of February 2007)
An interface with a 6-pole Western socket is provided for system diagnostics and process visualization. This
interface allows a data connection to be set up to the ROPEX visualization software using the ROPEX CI-USB-1
communication interface.
Only a ROPEX communication interface is allowed to be connected to the diagnostic interface.
Connecting another device (e.g. a telephone cable) could result in malfunctions or damage to the
controller.
The ROPEX visualization software is described in a separate document.
10.13 Booster connection
All controllers manufactured up to January 2007 only have an optional connection for an external switching
amplifier (booster) (
section 5.2 "Modifications (MODs)" on page 10). Modification 26 (MOD 26) must be
installed in the controller for this purpose.
A booster connection is provided as standard on all RES-409 controllers manufactured as of February 2007.