Controller functions
Version 1
RES-409
Page 33
0005
Heatup
time and
set point
START with specification of heatup time and selection of set point
Premature "STOP" if heatup time = 0
(
section 10.3.2 "START / STOP command "START" signal" on page 34)
0006
0…40
Store calibration temperature (in °C)
0007
As of
Feb. 2007:
3…99
Up to
Jan. 2007:
3…20
Store temperature monitoring values (in K), simultaneously changes upper and
lower temperature tolerance band limits
0008
0
1
2
3
4
5
6
7
10
11
12
13
14
15
Store alloy/range (heatsealing band alloy TCR/temperature range):
TCR = 1100ppm/K, max. temperature range 200°C
TCR = 1100ppm/K, max. temperature range 300°C
TCR = 1100ppm/K, max. temperature range 400°C
TCR = 1100ppm/K, max. temperature range 500°C
TCR = 3500ppm/K, max. temperature range 200°C
TCR = 3500ppm/K, max. temperature range 300°C
As of February 2007:
TCR = 3500ppm/K, max. temperature range 400°C
TCR = 3500ppm/K, max. temperature range 500°C
Rotary coding switch setting applies
TCR, temperature range, max. set point is variable
(see addresses 000A, 000B, 0014)
TCR = 780ppm/K, max. temperature range 200°C
TCR = 780ppm/K, max. temperature range 300°C
TCR = 780ppm/K, max. temperature range 400°C
TCR = 780ppm/K, max. temperature range 500°C
The following CAN messages are only available on controllers manufactured as of February 2007:
0009
0
1
2
Hold mode: OFF
Hold mode: ON
Hold mode: 2 seconds
(
section 10.6 "Hold mode" on page 43)
000A
400…4000
Variable temperature coefficient (TCR in ppm/K)
(applies if address 0008 contained the value 11 (dec))
000B
200…500
Maximum set point (in °C)
(applies if address 0008 contained the value 11 (dec))
000C
0
1
2
"Temperature OK" bit: OFF
"Temperature OK" bit: ON if set = actual
"Temperature OK" bit: ON if set = actual with latch function
(
section 10.9 "Temperature monitoring / "temperature OK" bit (as of February
000D
3…99
Store lower temperature tolerance band limit
000E
3…99
Store upper temperature tolerance band limit
Address
(hex)
Value
(dec)
Meaning