Maintenance
Version 1
RES-409
Page 59
[X] As of February 2007:
With ROPEX visualization software or via CAN-Bus interface only.
12
Maintenance
The controller requires no special maintenance. Regular inspection and/or tightening of the terminals – including
the terminals for the winding connections on the impulse transformer – is recommended. Dust deposits on the
controller can be removed with dry compressed air.
Measuring impulse
length
[X]
Measuring impulse length: 1.7ms
Temperature
diagnosis
[X]
Temperature diagnosis: OFF
Heatup timeout
[X]
Heatup timeout: OFF
Output 1
[X]
„Temperature OK“-Bit:
aktive if T
act
= T
set
Hold mode
[X]
Hold mode: OFF
DIP switch
for identifier and
baudrate
As of February 2007:
Identifier = 0
Baudrate = AutoBaud
Termination = ON
Up to January 2007:
Identifier = 1024
dez
Baudrate = 205kBaud
Termination = ON
3