Controller functions
Page 46
RES-409
Version 1
The "OUTPUT" LED blinks repeatedly while the "AUTOCOMP" function is running and the actual value output
(terminals 17+18) is set to 0…3°C (corresponds to approx. 0VDC).
3.
"AUTO"
(as of software revision 102)
This setting causes the "AUTOCOMP" function to be automatically started as soon as "AUTOCAL" has been
successfully executed.
Mode
AUTOCAL
command
1
t
t
0
0
AUTOCAL
Lit
t
OFF
<2.0s
AUTOCOMP
"AUTOCAL"
t
OFF
LED
Lit
"OUTPUT"
LED