Startup and operation
Page 22
RES-409
Version 1
9
Startup and operation
9.1
View of the controller
9.2
Controller configuration
The controller must be switched off in order to configure the coding switches and plug-in jumpers.
9.2.1
Configuration of the DIP switches for secondary voltage and current
Automatic configuration (AUTORANGE)
(controllers manufactured as of February 2007)
The secondary voltage and current ranges are automatically configured by the automatic calibration function
(AUTOCAL). The voltage is configured in the range from 0.4VAC to 120VAC and the current in the range from
30A to 500A. If the voltage and/or current are outside the permissible range, a detailed error message appears
on the controller (
see section 10.16 "Error messages" on page 52).
Configuration with DIP switches
(controllers manufactured up to January 2007)
Set the DIP switches for matching the secondary voltage U
2
and the secondary current I
2
to the correct position
for
your
application.
You can find the exact configuration of the DIP switches in the ROPEX Application Report calculated
for your particular application.
Terminals
LEDs
Coding switch
Plug-in jumper
Nameplate
CAN plug
Coding switch
for CAN parameters
!
!