Controller functions
Page 42
RES-409
Version 1
10.5
Temperature meter (actual value output)
The RES-409 supplies an analog 0…10VDC signal, which is proportional to the real ACTUAL temperature, at
terminals 17+18.
Voltage values:
0VDC
0°C
10VDC
300°C or 500°C
(depending on controller configuration)
The relationship between the change in the output voltage and the ACTUAL temperature is linear.
RES-409
17
max. 5mA
18
0V
R=33ohm
Actual value
output
0…10VDC
-
+
0…10VDC
Temperature
meter
e.g. ATR-3
Bereich 0 - 300°C
1
2
3
4
5
6
7
8
9 10
300
Te
m
p
er
a
tu
r
T
°C
20°C
"ZERO"
VDC
Spannung U
60
90
120
150
180
210
240
270
0.66V