Read This Section Whenever You Face a Problem (FAQ)
79
Chapter 4 Appendix
Chapter 4 Appendix
Is the Activity LED lit?
If the Activity LED for the Ethernet connector is not lit, the
network connection has not been made correctly. Check
whether the network routing is appropriate. Try connect-
ing the computer and the machine to the same hub, or
connecting them directly using a crossover cable. If this
makes it possible to perform printing, it means the problem
is in the network itself.
Are the network settings correct?
If output is not possible even though the Activity LED is on, make sure the IP address and other settings are
correct. The settings on both the machine and the computer must be appropriate. Redo the settings by check-
ing that the IP address does not conflict with the IP address for another device on the network, that the port
setting for the RIP & PRINT MANAGEMENT SOFTWARE specifies the IP address set on the machine, that the
settings have no typing errors, and for other such problems.
P. 47, "Viewing Information about the System of This Machine"
“First Step Guide”
Did the RIP & PRINT MANAGEMENT SOFTWARE exit abnormally?
Make sure the RIP & PRINT MANAGEMENT SOFTWARE is running correctly, and then switch the sub power
switch off and back on.
“Roland VersaWorks Dual Installation Guide”
Is the temperature of the room too low?
Use the machine in an environment where the temperature is 20 to 32°C (68 to 90°F).
The flat table does not move
Is something stuck in one of the movable axes (X, Y, or Z)?
Check whether something has become caught and is interfering with operation.
Are any covers open?
Close the front cover and panel cover during startup and printing. In the interest of safety, the flat table does
not move if any cover is open during startup or printing.
The head gap sensor does not detect the media
Is something covering the head gap sensor or has it attracted dust?
Check whether something is interfering with the head gap sensor's detection.
Activity LED