3-38
19
Fix the Pump Cover and Panel Cover.
Turn on the main power, then turn on the sub power while
pressing the left, right and down keys to enter the
Service Mode.
MENU
SERVICE MENU
+
MENU
17
Clear the pump times.
Select [SERVICE MENU] > [HISTORY MENU] >
[MOTOR GROUP] > [PUMP TIMES] > [CLEAR], and
press the [ENTER] key.
18
Select [SERVICE MENU] > [I/S MENU] > [PUMP
CHECK], and perform [PUMP SUCTION] and [PUMP
RELEASE] to check the pumps work correctly.
[ ]
SERVICE MENU
HITORY MENU
HITORY MENU
MOTOR GROUP
PUMP TIMES
9134 times
[ ]
PUMP TIMES
CLEAR
[ ]
SERVICE MENU
I/S MENU
I/S MENU
PUMP CHECK
PUMP CHECK
PUMP SUCTION
PUMP CHECK
PUMP RELEASE
[ ]
When fixing the Panel
Cover, fix the sensor on
the back side of the Panel
Cover and connect the
flexible cable on the
Panel Board.
PANEL COVER
< Back Side >
FLEXIBLE CABLE
SENSOR
PUMP COVER
16
Содержание VersaCamm VP-300
Страница 39: ...2 4 2 MAIN BOARD_Arrangement Diagram Soldering Side ...
Страница 50: ...2 15 2 SERVO BOARD_Arrangement Diagram Soldering Side ...
Страница 58: ...2 23 2 2 5 SUB BOARD It indicates the version of the Board SUB BOARD_Arrangement Diagram Component Side ...
Страница 102: ...3 39 Move the Head Carriage by hand to the lock position HEADCARRIAGE Fix the I S Cover SCREW I SCOVER HOOK 20 21 ...
Страница 222: ...7 2 7 Unpacking Manual etc CD ROM etc ...