START-S12
Technical manual
-7-
1.1
Description of the electrical connections
Earth
1
Earth
230 Vac (N)
2
230 Vac 50Hz, power supply, neutral
230 Vac (L)
3
230 Vac 50Hz, power supply, phase
Signal light
4
230 Vac Signal light
Max power 40 W
For the connection of a 12 Vac lamp or 230Vac signal ligth:
See the par 3.2, page number 12
5
6
Signal light
7
Test
8
Isolated contact for TEST / Interlock command
Test
9
Isolated contact for TEST / Interlock command
Out 12 Vac
10
12÷14 Vac output 800mA for accessories
Out 12 Vac
11
12÷14 Vac output 800mA for accessories
LSO
12
Open limit switch
LSC
13
Closing limit switch
Stop
14
STOP
Photo A
15
PHOTO-A closing
Safety edge
16
Safety or unfolding
Open
17
OPEN
Close
18
CLOSE
Start
19
START
Costa
20
SAFETY edge - NC / 8k2 contact
Common
21
Common Services Safeties
Common
22
Antenna Socks / Common-Services-Safeties
+ Antenna
23
+ Antenna
Switch Slow OP
24
Slow down switch OPEN
Switch Slow CL
25
Slow down switch CLOSE
Pedestrian
26
Partial opening / Interlock input
Common
27
Common Services Safeties
Out + 12 Vdc
28
12Vdc 60mA
Out - 12 Vdc
29
Output - 12Vdc 60mA
Photo A
30
Photo-A closing
Содержание START-S12-M
Страница 30: ...START S12 Manuale tecnico 30 10 Note ...
Страница 63: ...START S12 M Technical manual 30 10 Note ...
Страница 95: ...START S12 Technical manual 30 10 Note ...
Страница 128: ...START S12 Instrución 31 10 Note ...
Страница 129: ...START S12 Instrución 32 ...
Страница 130: ...START S12 Instrución 33 ...
Страница 164: ...START S12 Notice d emploi 31 10 Note ...
Страница 165: ...START S12 Notice d emploi 32 ...
Страница 166: ...START S12 Notice d emploi 33 ...