START-S12-M
Technical manual
-19-
T 01
T 03
T 02
T 04
T 11
t = 0 s
T 12
You can see how to program the control unit with
T
function:
SET
UP
DESCRIPTION
STANDARD
- seconds -
T 01
Set up the fully opening time of the door/gate
value from 0,1 s
4,0
T 02
Set up the opening time of partial opening
value from 0,1 s
3,0
T 03
Set up the start position of OPEN decelerating time
value from 0,1 s
2,0
T 04
Set up START position of the ClOSINg deceleration time
value from 0,1 s
1,0
T 11
Set up start position of deactivation of the photocelle.
It is not considered if S03 is set in 1
value from 0,1 s
0,5
T 12
Deactivation Time of the input SAfETY EDgE (term.S16) from starting
of lSO.
This function is useful in case of anti-folding to avoid the unroll
of the curtain which can temporary cover the photocell and the door
will start opening again.
1,0
5.2
Working time