Arbitrary and Function Generator
R&S AM300
E-1007.9922.12
6-176
Operating manual, 02/2005
Display in the case
of frequency
coupling
In the case of frequency coupling the currently applicable output frequency is
displayed below the channel name CH1 in the parameter field, e.g. "Freq: 1
kHz", and the currently applicable start phase is displayed below the channel
name CH2, e.g. "dPhase: 0 deg".
When frequency coupling is switched off, the currently applicable output
frequency of the channel is again displayed below the channel name CH2.
Dependences in the
case of frequency
coupling
When channel frequency coupling is switched on and off, the R&S AM300 is
reconfigured. This leads to differences in the availability of certain functions .
Frequency
coupling switched
on
(default setting):
Square Low Jitter
waveform available only in both channels at the same
time
Pulse
waveform can be set in both channels, but must have the same
pulse width
Frequency
coupling switched
off
:
Different frequencies can be set in the channels. Note that there is no
rigid phase coupling
Modulation mode and Sweep mode are not available
Different pulse widths may be set for the
Pulse
waveform
"Sample Accurate" Arbitrary mode is available in CH1 only
Square Low Jitter
waveform is available in CH1 only, but may be
combined with other waveforms in CH2
Switching all
coupling off
•
In the
submenu
press the
function key
.
Every coupling in channels CH1 and CH2 is switched off including
frequency coupling. The respective settings in channel CH1 are still
active in channel CH2. However, you can once more set the parameters
individually in each channel.