EN
75
GENERAL
BATT.CHARGER
BATTERY
PANEL
ENTER
ESC
LINE BLACKOUT
LINE LACK
HIGH VREG
OVER TEMPERATURE
ENTER
ESC
LINE BLACKOUT
TOTAL:
STATUS:
COUNTER:
ENTER
ESC
0
RUN
----
----
LINE BLACKOUT:
Shows the number of blackouts
detected in the mains voltage.
STATUS:
ON:
(if no mains power)
OFF:
(if there is mains power)
LINE LACK:
Shows the voltage surges (gaps) detected.
STATUS:
ON:
(voltage hole detected in the last 60 seconds)
OFF:
(regular mains voltage)
HIGH VREG:
shows the number of overvoltage instances
detected in the internal voltage regulator (used by the
battery charger)
STATUS:
ON:
(actual voltage too high)
OFF:
(voltage within limits)
OVER TEMPERATURE:
Displays the number of over-
temperature instances detected (exceeding the maximum
limit allowed by B71/PBX)
STATUS:
ON:
(temperature too high)
OFF:
(temperature within limits)
To see/modify the other functions, move onto the one
required (using the
T
and
S
keys) and repeat the
same procedure.
0
STOP
ENTER
ESC
-----
-----
LINE BLACKOUT
TOTAL:
STATUS:
COUNTER:
0
RESET
ENTER
ESC
------
------
LINE BLACKOUT
TOTAL:
STATUS:
COUNTER:
STOP:
interrupts the count
RESET:
resets the count, keeping it at zero
Use the
-
key to go back in the sequence RESET > STOP
> RUN
RECOMMENDED SETTING:
RUN
Return to the previous menu
11.18 Alarms menu
The indicated data is only indicative.
11.18.1
General alarms