EN
63
MAINTENANCE ENABLED
TARGET
: indicates how often the set discharge cycle will be
performed.
ACTUAL
: indicates the elapsed time. Once the target is
reached, a new discharge cycle starts again.
Period of repetition of forced operation in battery mode: from 10 to 100 days (G).
MAX
: when the central unit is powered by battery, if the charge drops to 70% the central unit (outputs OUT1/OUT2) is
disconnected; the battery life is maximized. The control unit will be powered again if the charge reaches 75%.
MIN
: when the central unit is powered by battery, if the charge drops to 50% the central unit (outputs OUT1/OUT2) is
disconnected; this deep discharge causes a reduction in battery life. The control unit will be powered again if the charge
reaches 65%.
WARNING!
Choose this setting only in the case of installations where frequent battery change is foreseen
(e.g.: seasonal installations)
RTM
: it is the same as MIN, but in addition if B71/PBX has disconnected the central unit for low battery, the reception
TK F HTRRFSI KWTR '5'=79(( FQQT\X YMJ X\NYHMNSL TS KTW YMJ IZWFYNTS TK RNSZYJX YNRJ STY RTINܪFGQJ FSI
then returns to switch off the central unit.
9MJ [FQZJ HFS GJ RTINܪJI \NYM YMJ TW PJ^X
9MJ [FQZJ HFS GJ RTINܪJI \NYM YMJ TW PJ^X
Indicates the elapsed time. Once the target has been reached, a new discharge cycle starts.
Return to the previous menu
Return to the previous menu
ENABLE
TARGET
ACTUAL
ON
10G
0G
ENTER
ESC
Indicates the current charge percentage.
Return to the previous menu