Menu
The indicated data is only indicative
11.1Welcome menu
B71/PBX36
R2.20
(TSܪLZWFYNTSXJQJHYJIKWTRRJSZ
- B71/PBX24
if VOLTAGE = 24V
- B71/PBX36
if VOLTAGE = 36V
NOTE:
this holds true for the FULL-SOLAR version as
well (view the version selected from jumper
J1: PBX24/
BOX DISCONNECTED - PBX36/BOX CONNECTED
)
WARNING!
If the
ERROR
message appears, check the
battery voltage selection (
SETTINGS menu >> BATTERY >> VOLTAGE
) and the position of jumper J1.
If the time and date have been set (par. 11.14, DATE AND TIME menu) or if B74/BCONNECT or B71/PBX/RTCC are
connected and provide the exact time, pressing the
ENTER
key switches to the date and time display and vice versa.
After 5 seconds the model and FW version will be displayed again.
If the time is maintained only by the internal management of B71/PBX (without accessories updating it, e.g.
due to disconnection of B74/BCONNECT from the WiFi router) a line is displayed above the date and time.
11.2 Battery charger status menu (examples) - CONSULTATION ONLY
The indicated data is only indicative
-BAT+
FW version
Closed padlock:
password protection active
Open padlock (hook turned to the left):
password
protection disabled
Current supplied (A), with a negative mark
Battery charging current(A), with a positive mark
WARNING!
• If the Power Box (initially disconnected) is powered,
FSI YMJ GFYYJW^ NX HTSSJHYJI ܪWXY YMJ [FQZJ \NQQ GJ XJY
at
C75%
(where the "C" indicates that this is a virtual
charge, not measured) and voltage will be supplied on
output OUT1/OUT2 (the control unit will be powered).
• If the Power Box is powered from the transformer or
XTQFW UFSJQ ܪWXY YMJS YMJ GFYYJW^ NX HTSSJHYJI YMJ
value will be
C40%
(where the "C" indicates that this
is a virtual charge, not measured) because the real
charge status isn't known and, in any case, there is
another supply source (mains or solar panel) that can
power the control unit.
If the mains/panel voltage is disconnected in this
situation, the battery will carry on powering the
board by itself but there will be no voltage supply to
the control unit. The voltage supply will only be
available when the charge level is higher than C75%.
Battery charge percentage (%)
ATTENTION:
the charge percentage is a reliable value
TSQ^ FKYJW HTRUQJYNSL YMJ ܪWXY HMFWLJ FSI PJJUNSL YMJ
battery permanently connected.
ATTENTION:
to indicate that the charging status is accurate,
YMJ HMFWLNSL GFW FUUJFWX TSQ^ FKYJW YMJ ܪWXY HMFWLJ NX
completed. At this point the "C" disappears as it is a
[JWNܪJIHMFWLJ
-
The batteries supply the control unit by providing
current to it, and to support the operation of the
B71/PBX
electronics
+
Battery charging in progress (current supplied
to the battery), positive mark. Charging batteries
from solar panels.
DISPLAYABLE INDICATIONS
--
pending evaluation on the charge phase
F1
constant current battery charging phase
F2
constant voltage battery charging phase
F3
battery charging phase for maintenance
+
Batteries charging in progress.
Batteries charging from the transformer.
DISPLAYABLE INDICATIONS
--
pending evaluation on the charge phase
F1
constant current battery charging phase
F2
constant voltage battery charging phase
F3
battery charging phase for maintenance
F3
Batteries in charge maintenance phase, with
HTSXYFSY RNSNRZR HZWWJSY 9MJ HZWWJSY NX ܪ]JI
and equal to 1/100C, so for 4.5Ah batteries it is
45mA, for 12Ah batteries it is 120mA.
69,9%
36.0V
-0.09A
-BAT+
Battery voltage (V)