Product description
The
B71/PBX
battery charger board provides the ROGER BRUSHLESS control units with the optimal power supply
voltage to allow the operation of the automated system, using a 12V battery pack and photovoltaic panels, not
supplied by the factory.
The
B71/PBX
NXJVZNUUJI\NYMF]ITY1()INXUQF^\NYMFLWFUMNHRJSZFSIXN]KZSHYNTSPJ^XKTWHTSܪLZWNSLFSI
analysing the operating values.
4
Version R2.20 updates
1. mixed mains/battery management functions added (FLEX60...FLEX90), to use the battery as much as possible even when mains voltage is
present
2. improved battery charge management for versions with transformer, always choosing the best energy source for recharging
3. increased the maximum manageable battery capacity, from 15Ah to 30Ah
4. increased the maximum battery charging current when using solar power: from 2.4 amps to 3.0 amps
5. improved internal time management, with the addition of time zone compensation (useful when using B74/BCONNECT that does not access
NTP servers, providing UTC time)
6.
FIIJI5T\JW8F[JKZSHYNTSXYTX\NYHMTKKYMJHTSYWTQUFSJQNSFIJܪSFGQJYNRJXQTYGFYYJW^XF[NSLIZWNSLYMJSNLMY
7. added control functionality for new radio receiver accessory with RTCC (Real Time Clock Calendar) to be able to reactivate the control panel in
case of access during PowerSave time slot (future application)
8. added RTM BATTERY LIFE management mode which, by maintaining at 50% the battery charge threshold at which the control unit switches
TKKFQQT\XNSYMJHFXJTKNSXYFQQFYNTSTKYMJ'5'=79((FHHJXXTW^YTUT\JWNYKTWFYNRJTKRNSZYJXJ[JSNKYMJGFYYJW^NXܫFYFQQT\NSL
manoeuvring (a solution which further reduces, a priori, the battery life)
5
9JHMSNHFQXUJHNܪHFYNTSX
B71/PBX24/BOX
B71/PBX24/BOX/115
B71/PBX36/BOX
B71/PBX36/BOX/115
B71/PBX/BOX
MAINS POWER VOLTAGE
20V~
SEC1: 26V~
SEC2: 20V~
-
LEAD BATTERIES (not supplied)
2x 12V 4.5Ah
3x 12V 4.5Ah
(*)
MAX. MANAGEABLE BATTERY CAPACITY
30Ah
30Ah
30Ah
OPERATING TEMPERATURE
-20°C +55°C
-20°C +55°C
-20°C +55°C
DEGREE OF PROTECTION
IP66
IP66
IP66
DIMENSIONS
310x120x390h
310x120x390h
310x120x390h
WEIGHT (excluding the batteries)
6,9
6,9
3,4
PHOTOVOLTAIC PANELS (18V)
MAXIMUM SUPPLIED VOLTAGE UNDER
LOAD
18V
18V
18V
MAXIMUM APPLICABLE VOLTAGE TO
THE PAN1/PAN2 TERMINALS
22V
22V
22V
MINIMUM REQUIRED POWER
20W
20W
20W
MINIMUM NUMBER OF
PHOTOVOLTAIC PANELS THAT CAN
BE CONNECTED PAN1 / PAN2 (parallel
connection) (**)
1 (es: 1X20W)
1 (es: 1X20W)
2 (es: 2X30W)
(*) 2 or 3 batteries 12V 12Ah will be installed, depending on the control unit to be powered (respectively B70/2DC,
B70/2ML, B70/2B, B70/1DC or EDGE1, B70/1DCHP, CTRL, CTRL/P)
(**) If two panels are connected, they must be of the same type (identical)
WARNING! The use of solar panels with a voltage higher than that indicated will lead to a malfunction of the charging
circuit, with the risk of damaging the circuit and the batteries.
5.1 Orientation of the photovoltaic panels
SUD
40°
The photovoltaic panel must be oriented by adjusting its inclination so that it is
40°
with respect to the horizontal plane:
- towards the
SOUTH
, if the place of installation is North of the equator (Boreal
hemisphere)
- towards
NORTH
, if the place of installation is South of the equator (Southern
hemisphere).