EN
54
7
Electrical connections B71/PBX36/BOX - B71/PBX36/
BOX/115 - B71/PBX/BOX with 36V Brushless control units
(B70/1DCHP, EDGE1, CTRL, CTRL/P)
5JWKTWRYMJJQJHYWNHFQHTSSJHYNTSXNSXJVZJSHJFXXMT\SGJQT\XJJܪL
TERMINAL
DESCRIPTION
N
L
FUSE
230 0
B71/PBX36/BOX
: Connection to the 230V~ ± 10% mains power.
Fuse 5x20 T1A.
NOTE: not present in the
B71/PBX/BOX
version
N
L
FUSE
115 0
B71/PBX36/BOX/115
: Connection to the 115V~ ± 10% 60Hz mains power.
Fuse 5x20 T2A.
NOTE: not present in the
B71/PBX/BOX
version
SEC_1 SEC_2
4
3
2
1
Connection of SEC_1 to the secondary winding of the transformer (26V~), BLACK-BLACK wires
Connection of SEC_2 to the secondary winding of the transformer (19V~), BLUE-BLUE wires
NOTE: the connection is made by ROGER TECHNOLOGY in the factory.
NOTE: not connected in the
B71/PBX/BOX
version
OUT1
OUT2
5
6
7
8
Connect the OUT1 terminals to the SEC1 terminals of the control unit.
Connect the OUT2 terminals to the SEC2 terminals of the control unit.
Do not connect other devices to the OUT1, OUT2 terminals: they are dedicated to the brushless
ROGER control unit.
CAUTION
: in installations with
B70/1DCHP
control unit, make sure the + terminal of OUT1 is
connected to the terminal 7 of the control unit.
In installations with
CTRL
or
CTRL/P
control unit, make sure the + terminal of OUT1 is connected
to the terminal 6 of the control unit.
NOTE
YTHTSSJHYYMJ4:9YJWRNSFQNYNXSTYSJHJXXFW^YTTGXJW[JFUWJIJܪSJITWIJW
BATTERY
9 10
Connection to the 3x12V battery pack (not supplied).
The three batteries must be connected in series and must be of the same make and type.
Connect terminal 9 (-) to the NEGATIVE pole of the series (black cable) and the terminal 10 (+) to
YMJ548.9.;*UTQJTKYMJXJWNJXWJIHFGQJ8JJܪLZWJ
PAN1
PAN2
+
+
11 12 13 14
Connection to photovoltaic panels. Maximum two panels can be connected, in which case they
must be identical. If only one panel with a power greater than 50W is connected, make a jumper
between the two "-" terminals (11-13) and one between the two "+" terminals (12-14) in order to
INXYWNGZYJYMJUT\JWTSYMJNSUZYHNWHZNY5&35&3ܪL
The voltage applied to each pair of terminals must not exceed 22V .
WARNING: DO NOT CONNECT THE PANELS IN SERIES.
WIFI
Connection connector to the ROGER WiFi B74/BCONNECT module.
The B74/BCONNECT module allows updating the device firmware and consulting certain
measurements performed via the WEB application.
ADTSER
SERIAL expansion connector for accessories.
For future expandability, e.g. to connect B71/PBX/RTCC
WARNING!
• Before connecting the batteries, make sure jumper
J1
IJYFNQ'ܪLIJYFNQ'ܪLNX
CONNECTED
Ѭ<MJSYMJGTFWINXUT\JWJIKWTRYMJRFNSXFGFYYJW^TWNKYMJXTQFWJSJWL^NXXZKܪHNJSYFUMTYT[TQYFNHUFSJQYMJUWJXJSYFYNTS
page must display the code
B71/PBX36
. If there is an
ERROR
message, quickly change the battery voltage selection (
SETTINGS menu
>> BATTERY >> VOLTAGE
)
•
Make sure (
SETTINGS
menu
>> BATTERY >> CAPACITY
) the capacity (in
Ah
) of the batteries used has been set. If it hasn't, the battery
charger won't work properly, and the batteries may get damaged)
For further information, refer to the solar panel installation manual B75 series.