48
48
Z21
®_
Booster
This track default value is always of relevance if the control centre set-
tings cannot be automatically detected via the B-Bus or the CDE of if
the ”Auto Settings“ (CAN) option is deactivated. Please also refer to
Chapter: Configuration and firmware update via CAN and Z21
®
mainte-
nance tool.
Should a voltage default value other than 18 V or 14 V have already
been set using the maintenance tool or POM programming, then one
value of > 16 V is indicated by the colour green and one of > 16 V is
indicated by the colour red.
18 V is set as standard.
Reset to factory default settings
Should it be necessary to reset all of the settings to the factory default settings, press the STOP button
until the status LED flashes violet (i.e. red + blue flash at the same time). This triggers a resetting to the
factory default settings and the track output is activated automatically.
Status-LED
Colour
Status
Meaning
Blue
on (light)
Normal mode
with
CAN
and activated auto-settings,
i.e. the settings (voltage and RailCom
®
) are automatical-
ly accepted by the Z21
®
via CAN.
Blue
on, switch-
es slowly
between light
and dark
Normal mode
with
CAN
and
deactivated
auto-set-
tings, i.e. the settings (voltage and RailCom
®
) are NOT
automatically accepted by the Z21
®
via CAN.
The default values that are set in the booster are used.
Blue
on (dark)
Normal mode
with
B-Bus
,
CDE
or via CAN with a Z21
®
with an older firmware < V1.23 without ZCAN20 stack
(firmware update recommended).
The default values set in the booster are used.
Blue
flashing
STOP
, track voltage deactivated.
In Operation:
8010806920 neu.indd 48