12
CoaguChek
®
Pro II · Operator’s Manual
If you need help
Information about using the system, the screen menus,
and performing a test can be found in this manual.
When error messages appear on the screen, refer to
Chapter 9,
Troubleshooting
starting with
.
For all questions about the CoaguChek Pro II system
that are not answered in this manual, contact your
Roche Diagnostics representative. In order to expedite
troubleshooting, please have ready your CoaguChek
Pro II meter, its serial number, this manual, and all
related consumables when you call.
General note
The data and information provided in this manual are
current as of issue. Any substantial changes will be
incorporated in the next edition. If there is any conflict
of information, the package insert included with the
CoaguChek test strips shall prevail.
What can the system do
for you?
The CoaguChek Pro II system makes coagulation
testing easy. You only need to insert the code chip,
power the meter on, insert the test strip for the
CoaguChek PT Test or the aPTT Test, and apply a
small blood sample. The blood mixes with the reagents
on the test strip, and the meter determines when the
blood clots. Depending on which test parameter is
selected, the meter displays the results after
approximately one minute (PT) or after several minutes
(aPTT). After the measurement, the meter
automatically stores the test result, together with date/
time and patient ID (and operator ID, if that option is
enabled) to memory.
The CoaguChek Pro II meter displays test results in
units equivalent to laboratory plasma measurements.
Results may be displayed in the following ways:
¾
Parameter: aPTT
–
seconds
¾
Parameter: PT
1 Introduction
• 1
Содержание CoaguChek Pro II
Страница 1: ...CoaguChek Pro II Operator s Manual...
Страница 15: ...15 CoaguChek Pro II Operator s Manual u Related topics 3 4 Options setup 62 1 Introduction 1...
Страница 29: ...29 CoaguChek Pro II Operator s Manual 1 3 Overview of the meter elements E F G H I J A B C D E 1 Introduction 1...
Страница 44: ...44 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 122: ...122 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 140: ...140 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 146: ...146 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 168: ...168 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 184: ...184 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 190: ...190 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 204: ...204 CoaguChek Pro II Operator s Manual Page intentionally left blank...
Страница 205: ......