3 TME400
MANUAL TME400-VCF · EN04 · 2019 March 26th
48
3.1.4.
Battery replacement
In order to replace the battery, unscrew the large screw on the right side of the elec-
tronics with a large screwdriver or a coin.
Figure 10: Position of the battery housing
The meter is rotated in the next figure, showing the rear area in this figure below.
Now, you can pull out the battery holder with battery on a handle.
The battery can be removed vertically in relation to the battery holder by pulling
slightly. When installing the new battery, ensure that the polarity is retained for the
new battery.
Danger
The battery must only be replaced in a non-explosive atmosphere. Ensure
that the electronics are supplied with adequate ventilation with fresh air.