1 Introduction
MANUAL TME400-VCF · EN04 · 2019 March 26th
30
Perforated plate straightener
The following options are available for the straighteners:
Perforated plate straightener RMG L1 - L3
according to ISO 5167-1 and DIN 1952
Perforate plate straightener RMG LP-35
Characteristics
ISO/DIN
L1-L3
RMG LP-35
Hole diameter d
d
0.05 D
0.04 D
0.13 D
Plate thickness e
e
d
e = d
0.13 D
Plate clearance a
0.5 D
a
1 D
0.5 D
-
Opening ratio m
0.2
m
0.4
0.3
0.6
Dynamic pressure
loss
p
5 - 15 (c²
/ 2)
2 - 15 (c²
/ 2)
With the RMG turbine meters, these straighteners fulfill the requirements of technical
guideline G 13 and are approved with approval number D 81 / 7.211.10 for turbine
meters.
1.4.2.7.
Standards / guidelines
All RMG turbine meters have passed upstream perturbation measurements accord-
ing to OIML recommendation IR-32/89, Annex A, with slight and heavy upstream per-
turbation. Therefore, this meter design fulfills the installation conditions according to
technical guideline G 13, section 1. The PTB testing vol. 29 and 30, Testing of vol-
ume gas meters with air at atmospheric pressure and high-pressure testing rules ap-
ply as a testing requirement. The RMG turbine meter TME400 conforms to EN12261.
The measuring accuracy in the range of 0.2 Q
max
to Q
max
is between
1.0 % to 1.5 %
(see
chapter 1.4.2.9 Measuring accuracy).
The TME400 has an electronic suppres-
sion by external shut down of the totalizer of the slow down cutoff of the turbine
wheel after the flow is stopped.
Содержание TME400-VC
Страница 6: ......
Страница 47: ...2 Installation MANUAL TME400 VCF EN04 2019 March 26th 41 Ex version...
Страница 48: ...2 Installation MANUAL TME400 VCF EN04 2019 March 26th 42 Ex version with current module...
Страница 49: ...2 Installation MANUAL TME400 VCF EN04 2019 March 26th 43 Non Ex version...
Страница 109: ...APPENDIX MANUAL TME400 VCF EN04 2019 March 26th 103 D Seal diagrams Will be added as soon as available...
Страница 111: ...MANUAL TME400 VCF EN04 2019 March 26th 105...