4 Operation
MANUAL TME400-VCF · EN04 · 2019 March 26th
56
Example:
Current mode F02 can be deactivated or activated on various settings. This is ad-
justed as follows:
0
Off (default)
1
No errors
2
Error 3.5 mA
3
Error 21.8 mA
4
0 - 20mA
If F02 = "0" is selected for the coordinate, the current output is switched off.
Note
With some coordinates, a number is assigned fixed values.
Instead of an adjustment with 0, 1, ..., these numerical values are shown di-
rectly. Changes are possible with the arrows
and
, then the next
higher or lower value is shown and can be adopted with
.
Example:
Digital output 2 pulse width (coordinate A22) can adjust the pulse width to 3 different
widths. The following values can be directly as an assignment:
20 ms
125 ms
250 ms
Содержание TME400-VC
Страница 6: ......
Страница 47: ...2 Installation MANUAL TME400 VCF EN04 2019 March 26th 41 Ex version...
Страница 48: ...2 Installation MANUAL TME400 VCF EN04 2019 March 26th 42 Ex version with current module...
Страница 49: ...2 Installation MANUAL TME400 VCF EN04 2019 March 26th 43 Non Ex version...
Страница 109: ...APPENDIX MANUAL TME400 VCF EN04 2019 March 26th 103 D Seal diagrams Will be added as soon as available...
Страница 111: ...MANUAL TME400 VCF EN04 2019 March 26th 105...