1 Introduction
MANUAL TME400-VCF · EN04 · 2019 March 26th
10
- Strength tests for components were conducted at 1.5 times the nominal pressure
for the pressure testing; the leak testing for the assembly was conducted at 1.1.
times the nominal pressure. Certificates were issued for successfully passed tests
- The maximum operating pressure and the permissible temperature range are
specified on the type plate of the device. Operation of the device is only permitted
within these specified ranges.
Danger
The following applies for work in hazardous areas (all zones):
-
The pulse generators of the turbine meter must be connected to intrin-
sically safe power circuit only.
-
Only tools that are approved for Ex Zone 1 are permitted for mainte-
nance and repair tasks.
-
Otherwise, work must only be carried out when there is not an explo-
sive atmosphere.
-
The risk of ignition due to impact or friction must be avoided.
-
Work on devices which are used in hazardous areas must be carried
out by qualified electrical engineers with special capabilities for work
in hazardous areas.