2
IMR02F04-E1
2. HOST COMMUNICATION
2.1 Host Communication Specifications
RKC communication
Interface:
Based on RS-485, EIA standard
Based on RS-422A, EIA standard
Connection method:
RS-485:
2-wire system, half-duplex multi-drop connection
RS-422A: 4-wire system, half-duplex multi-drop connection
Synchronous method:
Start-stop synchronous type
Communication speed:
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps
Data bit configuration:
Start
bit: 1
Data bit: 7 or 8
Parity bit: Without, Odd or Even
Stop bit: 1 or 2
Protocol:
ANSI X3.28-1976 subcategories 2.5 and A4
RKC communication protocol
Polling/Selecting type
Error control:
Vertical parity (With parity bit selected)
Horizontal parity (BCC check)
Communication code:
ASCII 7-bit code
Termination resistor:
Externally terminal connected (Example: 120
1/2 W)
Xon/Xoff control:
None
Maximum connections:
Up to 31 indicators
Interval time:
0 to 250 ms
Signal logic:
RS-485, RS-422A
Signal voltage
Logic
V (A)
V (B)
2 V
0 (SPACE)
V (A)
V (B)
2 V
1 (MARK)
Voltage between V (A) and V (B) is the voltage of (A)
terminal for the (B) terminal.